Skip to content
RemFixitSearch fault code

Error code

Mitsubishi Electric MXZ code F9

No approved translation for this record yet; showing the original text.

Meaning

2 connector open Abnormal if both 63H and 63L connector circuits are open for 3 minutes continuously after power supply 63H: High-pressure switch 63L: Low-pressure switch

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Disconnection or contact failure of connector (63H, 63L) on outdoor controller circuit board. (2) Disconnection or contact failure of 63H, 63L (3) 63H and 63L are operating due to defective parts. (4) Defective outdoor controller board

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.

Remote technician support

Get help from a technician over a video call.