Skip to content
RemFixitSearch fault code

Error code

Mitsubishi Electric MXZ code ED

No approved translation for this record yet; showing the original text.

Meaning

Serial communication error 1.Abnormal if serial communication between outdoor controller circuit board and outdoor power circuit board is defective.

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Breaking of wire or contact failure of connector CN2 between the outdoor controller circuit board and the outdoor power circuit board (2) Breaking of wire or contact failure of connector CN4 between the outdoor controller circuit board and the outdoor power circuit board (3) Defective communication circuit of outdoor power circuit board (4) Defective communication circuit of outdoor controller circuit board for outdoor power circuit board

Solution

Solution steps are available to members and are not shown on this page. Answer the questions to open the solution.

Remote technician support

Get help from a technician over a video call.