Error code
Mitsubishi Electric klima code UE
No approved translation for this record yet; showing the original text.
Meaning
during compressor operation. TH3: Thermistor <Liquid> Abnormal pressure of 63HS Abnormal if 63HS detects 0.1 MPa or less. Detection is inoperative for 3 minutes after compressor starting and 3 minutes after and during defrosting. 63HS: High pressure sensor
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
Defective TH3, condensing temperature T63HS Defective outdoor controller board Disconnection or contact failure of connector (63HS) on the outdoor controller circuit board Defective pressure sensor
Solution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.
Remote technician support
Get help from a technician over a video call.
Address of this page: https://www.remfixit.com/tr/mitsubishi-electric/klima/ue