Error code
Mitsubishi Electric klima code 4400
For your safety
This fault is rated critical. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.
Hazard area: mains voltage and refrigerant gas circuit
If there is a risk to life, first move to a safe place, then call 112. Do not follow remote repair instructions.
Call 112The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.
No approved translation for this record yet; showing the original text.
Meaning
Outdoor fan motor Abnormal if the rotational frequency of fan motor is not detected during DC fan motor operation. Fan motor rotational frequency is abnormal if; • 100 rpm or below detected continuously for 15 seconds at 68˚F [20°C] or more outside air temperature. • 50 rpm or below or 1500 rpm or more detected continuously for 1 minute. To find out the detail history (latest) Detailed Refer to "10-10. FUNCTION OF SWITCHES, codes Overvoltage error • Increase in DC bus voltage to: A12, 18N: 400 V
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
Abnormal increase in power source voltage Disconnection of compressor wiring Defective outdoor power circuit board Compressor has a ground fault.
Solution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.
Address of this page: https://www.remfixit.com/tr/mitsubishi-electric/klima/4400