Error code
Mitsubishi Electric klima code 4250
For your safety
This fault is rated high and involves an area that affects personal safety. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.
Hazard area: mains voltage and refrigerant gas circuit
Do not use the appliance and call an authorised service. If there is a risk to life, move to a safe place and see the emergency numbers.
The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.
No approved translation for this record yet; showing the original text.
Meaning
IPM alarm output / Bus voltage abnormality: 1 If over current, overheat or undervoltage of drive cirduit is detected by IPM during inverter operation. [Inverter error detail : 1] 2 If VDC 300 or VDC 760V is detected during inverter operation. [Inverter error detail : 1] 3 If IAC 39Amps is detected during inverter operation. [Inverter error detail : 11]
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
(1) The power supply voltage mal. (2) The wiring is defective. (3) The inverter / compressor tive.
Solution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.
Address of this page: https://www.remfixit.com/tr/mitsubishi-electric/klima/4250