Mitsubishi Electric klima code 1502

No approved translation for this record yet; showing the original text.

Meaning

Too low superheat due to low discharge temperature Abnormal if discharge superheat is continuously detected less than or equal to 5˚F [−15˚C] for 3 minutes even though linear expansion valve has minimum open pulse after compressor starts operating for 10 minutes.

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

Disconnection or loose connection of discharge temperature thermistor (TH4) Defective holder of discharge temperature thermistor Disconnection or loose connection of linear expansion valve’s coil Disconnection or loose connection of linear expansion valve’s connector Defective linear expansion valve

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.

Remote technician support

Get help from a technician over a video call.