Codes
- D7Error codeCurrent is flowing in the elevation control circuit to allow for the down relay controlling the elevation motor to activate
- D24Error codeTurns on dimly when power is first applied and becomes brighter as the large capacitor charges. When the LED is bright this indicates that the motor controller is ready to power the motor
- D29Error codeTurns on when excessive current passes through the FET. This LED implies that there is a short in the motor or motor wiring
- D30Error codeSPD
- D32Error codeTurns on when the current flowing through the motor reaches the circuit set maximum. This indicates that the system is loaded to or beyond its capacity
- D33Error codeTurns on when the transformer secondary that is attached to power ground outputs power. This indicates that the low voltage transformer is working and implies that the “hot side” control electronics are active
- D34Error codeVCON
- D50Error codeMotor AV applied to DC Buss (Relay output is activated)
- F3Error codeFrame & Lifesprings
- T3Error codeFrame & Lifesprings