Kumtel All models error codes
Codes
- FLT01Error codeA nonrecoverable microprocessor error has occurred
- FLT02Error codeAn Invalid Configuration fault occurs if a configuration parameter is set to an illegal value or combination of values. See the Configuration Fault Codes on page 141
- FLT03Error codeAn MP Output fault occurs if an internal error is detected in the circuit that removes motion producing power from the drive terminals
- FLT04Error codeA Reset Powerup fault occurs if the reset type is configured for Manual or Manual Monitored and the Reset In input is detected _ as ON when power is cycled
- FLT05Error codeA Feedback 1 fault occurs if any of these conditions are detected at encoder 1: • An open wire is detected. • A short-circuit is detected. • A sine/cosine fault exists, that is the amplitude of the sine signal squared plus the amplitude of the cosine signal squared is not equal to a constant value. • The feedback signals indicate a frequency greater than or equal to 100 kHz for a Sine/cosine encoder or 200 kHz for a incremental encoder. • Illegal encoder signal transitions are detected. • Incorrect Overspeed Response Time setting (refer to Table 15 on page 47)
- FLT06Error codeA Feedback 2 fault occurs if any of these conditions are detected at encoder 2: • Illegal encoder signal transitions are detected. • The feedback signals indicate a frequency greater than or equal to 200 kHz
- FLT07Error codeA Dual Feedback Speed fault occurs if an error is detected between the speed from the first encoder and the speed from the second encoder. Valid speed-comparison values are determined by the configured Feedback Speed Ratio and Feedback Speed Tolerance
- FLT08Error codeA Dual Feedback Position fault occurs if a discrepancy is detected between the relative position change of encoder 1 and the relative position change of encoder 2 since the last SS Reset
- FLT10Error codeSS OUT nn (1)
- FLT11Error codeA Deceleration fault occurs if the speed is detected at greater than the limit specified for the configured Stop Delay [Maximum Stop Time] when the configured Stop Category is Safe Stop 1 or 2
- FLT12Error codeA Stop Speed fault occurs when the drive is configured for a Stop Category that includes Standstill Speed checking (Safe Stop 1 or 2, and Safe Torque Off with Standstill Speed Checking) and the detected speed is greater than the configured Standstill Speed at the end of the configured Stop Delay [Maximum Stop Time]
- FLT13Error codeIf the drive is configured for a stop type that includes stopped speed checking, a Motion After Stop fault occurs if either of the following is detected after the system is stopped and the door has been unlocked: • Speed greater than the configured Standstill Speed • A position change greater than the configured Standstill Position limit
- FLT14Error codeSLS IN
- FLT15Error codeSLS OUT
- FLT16Error codeMotion Faults
- FLT21Error codeMonitor Fault
- FLT22Error codeDC OUT
- FLT24Error codeLOCK MONITORING
- FLT25Error codeESM IN
- FLT27Error codeAn Encoder 1 Voltage fault occurs if the encoder voltage at encoder 1 is detected as out of range
- FLT28Error codeAn Encoder 2 Voltage fault occurs if the encoder voltage at encoder 2 is detected as out of range