Kohler jeneratör kontrol paneli All models error codes
Codes
- A1Error codeSiteTech. ‡
- at70Error codeK1 relay, LED1 lights, and fault lamp
- at100Error codeVerify that the % load is steady at 100% for approximately 25 seconds. Verify that the % load is metering correctly. Verify that the overload percent is set at 10% or more below indicated level. Verify that the load management device is communicating with the generator set controller
- B1Error codeRbus Devices B1 Communication Errors
- B2Error codeCommon Fault
- B3Error codeLow Battery Voltage Warning
- B4Error codeRbus Devices B4 Communication Errors
- B5Error codeRbus Devices B5 Communication Errors
- B6Error codeNormal Source Failure
- D02Error codeLow Fuel (Level or Pressure) Warning, Digital Aux. Input D02 **
- D03Error codeLow Coolant Temperature, Digital Aux. Input D03 **
- D09Error codeLow Fuel Pressure Shutdown, Digital Aux. Input D09 (125RZG only)
- E0Error codeController memory failure.
- een85Error codeVerify that the load is not intermittently dropping below 85%. Verify that the load remains above 90% for at least 40 seconds. Verify that the % load is metering correctly. Verify that the overload percent is set at 10% or more below indicated level. Verify that the load management device is communicating with the generator set controller
- F2Error code3-amp controller fuse protects the controller circuit board, speed sensor, and lamp circuit board
- han30Error codeK1 relay, LED1 lights, and fault lamp
- hes103Error codeK1 relay, LED1 lights, and fault lamp
- K3Error codeK3 Run relay energizes du
- K20Error codeIs voltage present at the starter motor?
- L1Error codeVolts L1-L2 (AB) High Shutdwn †
- M4Error codeFuel Valve Relay
- M7Error codeGround Fault Detected
- OB1Error codeOB1 CommLoss (RBUS device‡)
- OB2Error codeOB2 CommLoss (RBUS device‡)
- OB3Error codeOB3 CommLoss (RBUS device‡)
- OB4Error codeOB4 CommLoss (RBUS device‡)
- P4-1Error codeLow oil pressure input signal
- P4-3Error codeAnticipatory high coolant temperature input signal
- P4-5Error codeMagnetic pickup sensor low (ground)
- P4-6Error codeMagnetic pickup sensor high
- P5-3Error codeSpeed sensor ground
- P5-6Error codeV+ Speed sensor
- P5-7Error codeLow oil pressure output signal
- P5-8Error codeAnticipatory high coolant temperature output signal
- TB1Error codeTB1 Terminal strip for accessories suc switch, a remote alarms, etc. Ref information on c TB1 terminal stri
- TB3Error codealarms, etc. Refer to the wiring diagrams for information on connecting accessories to the TB1 terminal strip