Hyundai Himsen gemi jeneratörü All models error codes
Codes
- be1Error code※ Exhaust gas temperature deviation is highe temperature deviation could be acceptable be characteristic. So if Pmax is similar, it could be 1. Pilot Injector 2. GAV 3. Cylinder pressure sensor
- co1Error code※ In diesel mode, if charge air pressure is hig mode, proper air quantity is important. Higher charge air pressure could cause abno charge air pressure could cause abnormal co 1. Sensor failure 2. Waste gate control failure 3. Charge air leakage 4. Room ventilation and suction temp 5. Turbo charger 6. Abnormal load signal from PMS
- is1Error code※ Supplied gas pressure of GRU is charge air pressure is 1 bar and it could be changed acc engineer. If gas pressure could not follow set 1. Abnormal instrument air pressure to IP converter (normal 7 bar) 2. Sensor failure 3. Abnormal control signal (4-20mA) to IP converter 4. IP converter failure 5. Regulator failure or leak
- LT3Error code※ DF engine diesel mode is similar with d of Micro Pilot system and LT 3-way valve. 1. Exhaust gas deviation (Diesel mode) Exhaust Gas Temp Deviation 2. Pmax deviation on load operation (Diesel mode)
- mi1Error code※ Fuel gas supply from GAV to each cylinder condition. If there is trouble on GAV, fuel gas combustion condition will be abnormal like mi 1. If GAV could not be closed completely because of strange substance, fuel gas will be supplied continuously to cylinder and Pmax, exhaust gas temperature will be increased. 2. If ‘open coil’ alarm is activated, GAV could not be open normally due to broken cable. If ‘over current’ alarm is activated, could estimate cable short or sol. Valve trouble in GAV. (Over current alarm can be checked after connect to the Controller by S/E)
- SV41Error code※ In case of slow turning failure, there are tw can be verified by activating SV41(Starting va (Slow Turning valve 2) manually. No rotation of flywheel during the Slow- turning Throttle v.v SV41 Regulator SV451
- to900Error codeAfter that, by operating only pilot injector, system will check normal operation of micro pilot system with monitoring engine rpm and each cylinder exhaust gas temperature. 1. HP pump motor is not rotated 2. HP pump is rotated but pressure could not build up or control properly