Error code
Ghibli endüstriyel süpürge All models code UA21
No approved translation for this record yet; showing the original text.
Meaning
Inverter over heating error- Inverter power circuit over heated
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
1. Verify the inverter fan is functioning properly and that the inverter has it cover on (if applicable). 2. Verify he basket movement restrictions. Possibly caused by the basket catching on something, motor seizing up, or bad bearings. 3. Check inside drain valve/ pump, make sure no debris has restricted valve movement. 4. Verify the inverter is clear of debris and the inverter fan is operating properly. Clean inverter. 5. Verify dip switches on the inverter are set correctly (if applicable). 6. Remove the motor pulley belt and spin the motor to test for bad motor bearings. 7. Isolate the inverter by disconnecting the motor and jumping out the klixons. Run Test Mode. 8. Verify that the motor windings are not shorted or open. 9. Verify the amperage draw across each leg of power going to the motor. Amperage draw should be similar. 10. Check for bad motor bearings. 11. Verify the integrity of the motor harness/ power coming into the inverter
Solution
Solution steps are available to members and are not shown on this page. Answer the questions to open the solution.
Remote technician support
Get help from a technician over a video call.
Address of this page: https://www.remfixit.com/tr/ghibliendustriyelsupurge/tum-modeller/ua21