Meaning
Short detected in the motor windings- A short in the motor or motor winding. This could be a short phase to phase, phase to housing, or phase to klixon
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
1. Verify the integrity of the motor discharge resistor and the Earth ground. Please refer to ST-112R* 2. Inspect the motor cable wiring from the inverter to the motor. 3. Verify the motor windings are not shorted or open. Phase to phase should read about the same. Phase to klixon should read open. Phase to motor housing should read open. 4. Verify the amperage draw across each leg of power going to the motor. Amperage draw should be similar