Meaning

Coast - to - stop komutu Alarm sıfırlama Trip komutu (Harici hata) Jogging işlemi Frekans ayarı 2 / Frekans ayarı 1 Motor 2 / Motor 1 DC fren komutu Tork sınırlayıcı 2 / Tork sınırlayıcı 1 Hat ve invertör arasındaki anahtarlama işlemi (50Hz) Hat ve invertör arasındaki anahtarlama işlemi (60Hz) yukarı komut AŞAĞI komutu TUŞ TAKIMI için yazma etkinleştirme PID kontrolü iptali Ters mod değiştirme 52 -2 için güvenlik kilidi sinyali TRQ kontrolü iptali Bağlantı etkinleştirme (RS -485, Bus) Evrensel DI Alma başlatma modu SY-PG enabled Synchronization command Zero speed command

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(BX): ON ........ The inverter output is cut off immediately and the motor will coast-to-stop. (No alarm signal will be output.) (RST): ON...... Faults are reset. • The inverter output is cut off and the motor coasts-to-stop. Alarm signal will be output. • This signal is held internally and is reset by inputting RST signal. • Used to protect overheating of external braking resistor. (JOG): ON .... JOG frequency is effective. (Hz2/Hz1): ON ..... Freq. (M2/M1): ON .......The motor circuit parameter and V/f characteristics are changed to the second motor's ones. (DCBRK): ON ..... The DC inUXction brake is effective. (In the inverter deceleration mode) (TL2/TL1): ON .... Torque limiter 2 is effective. (SW50(SW60)): ON The motor is changed from inverter operation to line operation. (SW50(SW60)): OFF The motor is changed from line operation to inverter operation. (UP): ON ........... The output frequency increases. (DOWN): ON .... The output frequency decreases. · The output frequency change rate is determined by ACC / DEC time. · Restarting frequency can be selected from 0Hz or setting value at the time

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.