Error code
Chigo All models code E2
No approved translation for this record yet; showing the original text.
Meaning
room temp sensor fault
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
1. Check whether the resistance of the sensor is normal (the resistance is 5КΩ in the normal temperature 25 ) ℃ , when it is abnormal the sensor should be replaced.2. Check whether there is short circuit or open circuit in the wire of the sensor, and whether the plug isconnected well, whether there is welding off or rosin joint on the electric control board, if there is any, it should be repaired.3. When the 1 and 2 are both normal, then the components or integrated circuit is damaged, the electric control board should be replaced
Solution
Solution steps are available to members and are not shown on this page. Answer the questions to open the solution.
Remote technician support
Get help from a technician over a video call.
Address of this page: https://www.remfixit.com/tr/chigo/tum-modeller/e2