Error code
Case All models code Cd27
For your safety
This fault is rated high and involves an area that affects personal safety. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.
Hazard area: pressure vessel
Do not use the appliance and call an authorised service. If there is a risk to life, move to a safe place and see the emergency numbers.
The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.
No approved translation for this record yet; showing the original text.
Meaning
Defrost Interval (Hours or Automatic)
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
Buz çözme başlatma için kullanıcı tarafından seçilen zaman aralıkları veya otomatik kontrol olmak üzere iki mod vardır. Kullanıcı tarafından seçilen değerler (KAPALI), 3, 6, 9, 12 veya 24 saat iken fabrika varsayılanı 12 saattir. Otomatik defrost, 3 saatte bir ilk defrost ile başlar ve daha sonra evaporatör serpantini üzerindeki buz birikimine bağlı olarak aralığı bir sonraki defrost için ayarlar. Bir başlatmanın ardından veya bir buz çözme işleminin sona ermesinden sonra, süre defrost temperature sensor (DTS) reading falls below set point. If the reading of DTS rises above set point any time during the timer count down, the interval is reset and the count- down begins over. If DTS fails, alarm code AL60 is activated and control switches over to the the return temperature sensor. The controller will act in the same man- ner as with the DTS except the return temperature sensor reading will be used. Defrost Interval Timer Value (Configuration variable CnF23): If the software is configured to “SAv” (save) for this option, then the value of the defrost interval timer will be saved at power down and restored at power up.
Solution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.
Address of this page: https://www.remfixit.com/tr/case/tum-modeller/cd27