Delta Electronics sunucu güç kaynağı psu All models error codes
Codes
- 09-30Error codeCommunication decoding method
- 09-70Error codeNode ID of AC motor drive
- 700-739Error codeTheoretical calibration for CH1
- 740-779Error codeTheoretical calibration for CH2
- B1Error code2 Fren Direnci Bağlantısı (opsiyonel)
- CH1Error codewhether the present difference is less than the absolute value of ERR DBW, and it _ checks whether the present difference meets the cross status condition. If the present difference is less than the absolute value of ERR DBW and it _ meets the cross status condition, the present error is counted as 0, and the PID algorithm is implemented. Otherwise the present error is brought into the PID algorithm normally
- CN503Error codeCommunication signals CN505 for PMbus
- D1Error codeError flag
- D2Error codeError code
- D2600Error codeModule status (0:Normal,1:Initializing,2:error)
- E2Error codeThe slave device in the scan list does not exist or is offline when AS01DNET-A is in master mode
- E4Error codeError detected in sequence of fragmented I/O data from the slave device
- E5Error codeThe slave device returns error when AS01DNET-A attempts to communicate with it
- F2Error codeToo low voltage of the work power
- F6Error codeInternal error; Flash or RAM check error
- F8Error codeError produced in factory manufacturing
- F9Error codeInternal error; EEPROM access failure
- k2Error codeAşırıyük 2 Motor aşırıyüklü. Yazılım Koruma Hatası
- MI3Error codeÇoklu-fonksiyon giriş 3
- S8Error codeCommunication timeout time
- SM1024Error codeError in data exchange connection 1 through AS- FEN02
- SM1025Error codeError in data exchange connection 2 through AS- FEN02
- SM1026Error codeError in data exchange connection 3 through AS- FEN02
- SM1027Error codeError in data exchange connection 4 through AS- FEN02
- SM1028Error codeError in data exchange connection 5 through AS- FEN02
- SM1029Error codeError in data exchange connection 6 through AS- FEN02
- SM1030Error codeError in data exchange connection 7 through AS- FEN02
- SM1031Error codeError in data exchange connection 8 through AS- FEN02
- SR1520Error codeRefresh after AS-FEN02 communication is done
- SR1528Error codeThe error code for data exchange through the AS- FEN02 connection 1
- SR1529Error codeThe error code for data exchange through the AS- FEN02 connection 2
- SR1530Error codeThe error code for data exchange through the AS- FEN02 connection 3
- SR1531Error codeThe error code for data exchange through the AS- FEN02 connection 4
- SR1532Error codeThe error code for data exchange through the AS- FEN02 connection 5
- SR1533Error codeThe error code for data exchange through the AS- FEN02 connection 6
- SR1534Error codeThe error code for data exchange through the AS- FEN02 connection 7
- SR1535Error codeThe error code for data exchange through the AS- FEN02 connection 8
- SR1536Error codeAS-FEN02/FOPC02 TCP current connection number
- T1Error codeW/T3 3-faz motor bağlantısı için AC sürücü çıkış terminalleri
- X1Error codeIndicates the status of Ethernet communication