Deep Sea Electronics generator kontrol paneli All models error codes
Codes
- 2-14Error codeNOTE: Due to module configuration the alarm message that appears on the display may be different. For further details of module configuration, refer to DSE Publication: 057- 251 DSEE400 Configuration Software Manual
- 2-63Error codeThe module received a fault condition from the engine ECU alerting about the SCR Inducement
- 2-80Error codeThe module received a fault condition from the engine ECU alerting that the HEST had activated
- 056-010Error codeOver Current Protection
- 056-076Error codeReading DSEGencomm Alarms
- 056-092Error codeBest Practices for Wiring Resistive Sensors
- 057-220Error codeOptions for Communications with DSE Controllers
- C37Error codeUnder the scope of IEEE 37.2, function numbers can also be used to represent functions in microprocessor devices and software programs. The controller is device number 11L-8000 (Multifunction device protecting Line (engine) -module). As the module is configurable by the engine OEM, the functions covered by the module vary.
- DM1Error codeDiagnostic Message 1 A DTC that is currently active on the engine ECU
- EEE37Error codeCharge Alt Failure IEEE 37.2 - 27 DC Undervoltage Relay
- ent51Error codeA device that functions when the ac input current exceeds a predetermined value, and in which the input current and operating time are inversely related through a substantial portion of the performance range
- gle78Error codeA device that functions at a predetermined phase angle between two voltages, between two currents, or between voltage and current
- Hz-0Error codeSynchronising will only occur when both the Frequency and the voltage differences are within acceptable limits - Indicated by ‘Tick’ marks on the top of the display. Then the moving bar display will show the phase difference. The engine speed will be automatically adjusted, altering the phase, until the moving bar enters the centre of the scope
- or25Error codeA synchronizing device produces an output that causes closure at zero- phase angle difference between two circuits. It may or may not include voltage and speed control. A synchronism-check relay permits the paralleling of two circuits that are within prescribed limits of voltage magnitude, phase angle, and frequency
- or46Error codeA device in a polyphase circuit that operates when the polyphase currents are of reverse-phase sequence or when the polyphase currents are unbalanced or when the negative phase-sequence current exceeds a preset value
- ous50Error codeA device that operates with no intentional time delay when the current exceeds a preset value