Chappee All models error codes
Codes
- A1Error codeFault with the room temperature sensor on the indoor unit
- A2Error codeFault with the temperature sensor in the middle of the indoor unit's evaporator
- A3Error codeFault with the temperature sensor at evaporator inlet
- A4Error codeFault with the temperature sensor at evaporator outlet
- A5Error codeIndoor unit condensate pump anomaly (fault with the drainage)
- A6Error codeFan motor fault in the indoor unit
- A8Error codeFault in the EEPROM module of the indoor unit
- A9Error codeAbnormal communication between the indoor unit and the outdoor unit
- AAError codeAbnormal communication between the indoor unit and the wired controller
- ADError codeIndoor frost protection
- BKError codeBK BK BK BK BK BR
- BLError codeWH BK BR BK BK BK
- BRError codeBK BK BK BK GN/
- C1Error codeFault with the environmental temperature sensor on the outdoor unit
- C2Error codeFault with the defrosting temperature sensor on the outdoor unit
- C3Error codeFault with the discharge temperature sensor on the outdoor unit
- C6Error codeFault with the suction temperature sensor on the outdoor unit
- C8Error codeFault with the temperature sensor in the middle of the outdoor condenser
- E1Error codeFour-way valve fault
- E2Error codeFault with the refrigerant temperature sensor on the outdoor unit
- E3Error codeExcessive discharge temperature protection
- E5Error codeCommunication error between the indoor Connection wire, main internal control panel, main ex
- E8Error codeCooling: protection of the outdoor unit against high temperatures
- F1Error codeFault with the inverter module protection (IPM)
- F2Error codeFault with the outdoor unit PCB protection (PFC) condenser
- F3Error codeFault with the compressor synchronism
- F4Error codeFault with the discharge temperature sensor
- F6Error codeFault with the outdoor temperature sensor
- F9Error codeFault with the outdoor unit EPROM
- FAError codeIntake temperature sensor error
- FHError codeLow discharge temperature protection
- FRError codeDo not allow the refrigerant to escape into the atmosphere or the
- GYError codeGN/ GN/ BL RD GN/ BL BL BK BK BK BK BK BK BK BK
- H1Error codeHigh pressure switch protection
- H4Error codeLow pressure switch protection
- J2Error codeAbnormal communication between the outdoor unit and the indoor unit
- J3Error codeAbnormal communication between the driver PCB and main PCB of outdoor unit
- J7Error codeFault with the outdoor unit EPROM
- P4Error codeCondenser overload protection (in cooling mode)
- P5Error codeDischarge temperature protection
- P6Error codeEvaporator overload protection (in heating mode)
- P7Error codeIndoor unit freeze protection (in cooling mode)
- P8Error codeOutdoor unit overcurrent protection
- X01Error codeX62 PE-2 PE-1 X41 X51 PE-4
- X2Error codeStatus LIN-Bus PWM 0-10
- X5Error codeX6 X7 X8 X10 X11
- X22Error codeXC01 X25 X21
- X32Error codeX115 X102 X103 X104 X1151
- X51Error codeX105 X101 X115 X1151 X111
- X81Error codeX102 X104 X114 X112