Bosch Rexroth tren fren sistemi All models error codes
Codes
- 10-11Error codeÜRETİM YERİ
- and24Error codeError in wiring: ● Loose connections or wire break ● Incorrect wiring of inputs and outputs ● Short circuit between both selection channels ● Short circuit between one or both selection channels and 24 V or 0 V
- C0200Error codeWhile command C0200 was executed, error in parameterization of P-0-4076 was detected
- C0702Error codeControl loops of motors with motor encoder data memory are adjusted to connected digital drive by activating controller parameters stored in it. Message C0702 on display of drive controller signals that no data memory is available at connected motor
- C2200Error codeError when starting or stopping command C2200
- C3200Error codeCommand C3200 can only be carried out for an asynchronous motor
- C3600Error codeCommand C3600 had been started when motor was still moving
- C7000Error codeDuring execution of command C7000 and within the scope of remote address assignment, an attempt is made to write corresponding addresses of CCD slaves ("S-0-1040, Drive address of master communication") such as parameterized in "P-0-1636, CCD: Command topology". This is impossible, as CCD slaves are not in phase 2
- DC24Error codeError in the external DC24 V voltage supply
- E2092Error codeMaster communication with synchronization ability (EtherCAT) If NC cycle time is greater than sercos cycle time, master communication master must toggle "IPOSYNC" bit of master control word; if this is not the case or takes place incorrectly, warning E2092 is generated
- E8058Error codeModule bus reaction E8058 is active; i. e. axis is locking drive enable because another drive in drive package is signaling an error
- F2Error codeAn F2 or F3 error occurred in a CCD slave and "error reaction active" has been set in "P-0-1600, CCD: configuration"
- F3Error codeParameterization for F3 error reaction is too low
- F7Error codeParameterization of tolerance time for reaction to F7 error is too low
- F8Error codeAn F8 error occurred in a CCD slave and "best possible deceleration" has been set in "P-0-1600, CCD: configuration" as reaction to an F8 error
- F8xError codeF8xxx error at high speeds (field weakening area) on a synchronous motor
- F81xError codeAfter a boot error (F81xx error) there was an attempt to switch to operating mode
- F2009Error codeParameter memory (programming module or internal memory) is defective so that error F2009 keeps reappearing
- F2048Error codeF2048 (Low battery voltage) is entered in addition to F2174 in error memory (P-0-0192). Encoder memory is not supplied with power because battery has no charge or there is cable breakage in power supply line
- F8022Error codeThere was an attempt to clear error "F8022 Enc. 1 error: sign. amplitude (can be cleared in ph.2)" in communication phase 4 (operating mode). This is only possible in communication phase 2 (parameterization mode)
- H2Error code● Power supply missing ● Device defective
- H14Error codeHardware defective
- H49Error codeGreen
- H52Error codeGreen
- H53Error codeGreen
- HCP01Error codeFaulty parallel connection module HCP01.1-P001
- HMU05Error codeMains voltage below the minimum value (connection voltage range, see documentation "Rexroth IndraDrive ML, drive systems with HMU05")
- HPC01Error codeFaulty motor/mains module (HPC01.1-MNxx)
- is1000Error codeRing buffer activated for the function "Synchronization on non-synchronous master communication" has detected an overflow. Over an extended period more data were removed than included or more included than removed. Normally, this is compensated for with a correction of nominal value of system time in drive controller. Maximum permanent difference between master communication cycle time and system timer in drive controller is 1000 ppm of master communication cycle time. A greater deviation always results in error F4142
- KTY84Error codeMotor temperature measured by temperature sensor KTY84 is below -20 °C (MPx17 and above: -40 °C)
- L1Error codeAxis: Different line lengths of the parallel connected power sections between the connections of the symmetry throttle HML and the motor connection busbar (L1/A1…L3/A3). Power supply: Different line lengths of the parallel connected power sections between the connections (L1/A1…L3/A3) of the mains throttle combination HNL / HNC / HNL and the mains busbar
- MPx16Error codeSpecial case for MPx16: Firmware upgrade to higher firmware version. This error occurs once at first start of drive after firmware upgrade
- MPx17Error codeAs of MPx17: Incorrect parameterization of "P-0-0468, Prewarning threshold of therm. motor load"
- MPx18Error codeAs of MPx18: Value of "P-0-0853, MMax. DC bus voltage, motor" is too low with respect to respective mains voltage
- of2Error codeSignals of motor encoder do not reflect motion process of axis; encoder cables of 2 drives possibly mixed up - or - Incorrect polarity of encoder signals
- of40Error codeAmbient temperature too high. Specified performance data is valid up to an ambient temperature of 40 °C
- or0Error codeDelay between selection channels exceeded during a selection or deselection
- or1MError codeDrive controller is defective
- P-0Error code4089.00.13, Master communication: IP address
- PF55Error code24-V voltage supply is applied
- PF58Error codeno error, no warning
- R4090Error code_ PUMP BASE PTFL250 FOT
- R8616Error codeREED SENSOR 2,5M
- R9000Error codePRESSURE SWITCH 716001 100 019-01714&
- R9002Error codeBLADD.ACCUMULATOR SB330-20A1/112A1-330&
- R9003Error codeEINBAUSATZ NG 8 0,5 BAR
- R9004Error codeDECKEL SM 12 L10/H200M5,8-19*BG/19152100
- R9006Error codeBLADD.ACCUMULATOR SB330-4,0A1/112C-330&
- R9007Error codeMOT-PUMP-CONN.KIT ABZPZ-S 1X/B35- 80/0&
- R9008Error codePILOT VALVE 2WRC 40 -1X/S/M-12*BG