Blue Box klima santrali All models error codes
Codes
- A1Error code0-100 % ECONCOOL Static Pressure Setpoint 0-5 "H2O SPSPCTST Requested Cool Stage 0-8 CLST TST _ Minimum Load Valve Relay Off/On MLV TST _ Compressor A1 Relay Off/On CMPA1TST Compressor A1 Capacity 20-100 A1CAPTST Two Circuit Start A1,B1 Off/On CMPABTST Compressor A2 Relay Off/On CMPA2TST Compressor A3 Relay Off/On CMPA3TST Compressor A4 Relay Off/On CMPA4TST Compressor B1 Relay Off/On CMPB1TST Compressor B2 Relay Off/On CMPB2TST Compressor B3 Relay Off/On CMPB3TST Compressor B4 Relay Off/On CMPB4TST Humidimizer 3-Way Valve Off/On RHVH TST _ Condenser EXV Position 0-100 % CEXVHTST Bypass EXV Position 0-100 % BEXVHTST
- A2Error codeVFD INFORMATION SUPPLY FAN VFD (VFD 1) 119 VFD1 Actual Speed % 0 to 100 % VFD1 SPD 119 _ VFD1 Actual Motor RPM 0 to 30000 VFD1RPM 119 VFD1 Actual Motor Freq 0 to 500 VFD1FREQ 119 VFD1 Actual Motor Amps 0 to 999 amps VFD1AMPS 119 VFD1 Actual Motor Torque -200 to 200 % VFD1TORQ 119 VFD1 Actual Motor Power -150 to 150 kW VFD1PWR 119 VFD1 DC Bus Voltage 0 to 1000 voltage VFD1VDC 119 VFD1 Output Voltage 0 to 1000 voltage VFD1VOUT 119 VFD1 Transistor Temp (C) 0 to 150 VFD1TEMP 119 VFD1 Cumulative Run Time 0 to 65535 hours VFD1RUNT 119 VFD1 Cumulative kWh 0 to 65535 VFD1KWH 119 VFD1 Last Fault Code 0 to 65535 VFD1LFC 119 EXHAUST FAN VFD (VFD 2) VFD2 Actual Speed % 0 to 100 % VFD2 SPD 119 _ VFD2 Actual Motor RPM 50 to 30000 VFD2RPM 119 VFD2 Actual Motor Freq 10 to 500 VFD2FREQ 119 VFD2 Actual Motor Amps 0 to 999 amps VFD2AMPS 119 VFD2 Actual Motor Torque -200 to 200 % VFD2TORQ 119 VFD2 Actual Motor Power -150 to 150 kW VFD2PWR 119 VFD2 DC Bus Voltage 0 to 1000 voltage VFD2VDC 119 VFD2 Output Voltage 0 to 1000 voltage VFD2VOUT 119 VFD2 Transistor Temp (C) 0 to 150 VFD2TEMP 119 VFD2 Cumulative Run Time 0 to 65535 hours VFD2RUNT 119 VFD2 Cumulative kWh 0 to 65535 VFD2KWH 119 VFD2 Last Fault C
- CO2Error codeZS CO2 Sensor Valid Status
- DL1Error codeSWITCH LOGIC: NO / NC Power Fault Input - Good Open/Close PWRFLOGC Close Filter Status Input - Clean Open/Close FLTSLOGC Open Post Filter Stat. In-Clean Open/Close PFLTSLGC Open IGC Feedback - Off Open/Close GASFANLG Open RemSw Off-Unoc-Strt-NoOv Open/Close RMTINLOG Open Enthalpy Input - Low Open/Close ENTHLOGC Close Fan Status Sw. - Off Open/Close SFSLOGIC Open Dmd.Lmt.Sw.1 - Off Open/Close DMD SW1L Open _ Dmd.Lmt.Sw.2 - Off Open/Close DMD SW2L Open _ IAQ Disc.Input - Low Open/Close IAQINLOG Open Fire Shutdown - Off Open/Close FSDLOGIC Open Pressurization Sw. - Off Open/Close PRESLOGC Open Evacuation Sw. - Off Open/Close EVACLOGC Open Smoke Purge Sw. - Off Open/Close PURGLOGC Open Dehumidify Sw. - Off Open/Close DHDISCLG Open SF Bypass Sw. - Off Open/Close SFBYLOGC Open PE Bypass Sw. - Off Open/Close PEBYLOGC Open
- E1Error codeTEST HUMIDIMIZER HumidiMizer 3-way Valve Condenser EXV Position Bypass EXV Position Condenser EXV Calibrate Bypass EXV Calibrate
- EC1Error codeEconomizer 1 Out Act. Curr. Pos. 0-100 % ECONOPOS Economizer 2 Ret. Act.Curr.Pos. 0-100 % ECON2POS Economizer 3 Out Act.Curr.Pos. 0-100 % ECON3POS Economizer Out Act.Cmd.Pos. 0-100 % ECONOCMD forcible Economizer Active ? No/Yes ECACTIVE Single Act CFM Ctl Activ No/Yes SACFMCTL forcible ECON DISABLING CONDITIONS Econ Out Act. Unavailable? No/Yes ECONUNAV Econ2 Ret Act. Unavailable? No/Yes ECN2UNAV Econ3 Out Act. Unavailable? No/Yes ECN3UNAV Enth. Switch Read High ? No/Yes ENTH DBC - OAT Lockout? No/Yes DBC STAT _ DEW - OA Dewpt.Lockout? No/Yes DEW STAT _ DDBD- OAT > RAT Lockout? No/Yes DDBCSTAT OAEC- OA Enth Lockout? No/Yes OAECSTAT DEC - Diff.Enth.Lockout? No/Yes DEC STAT _ EDT Sensor Bad? No/Yes EDT STAT _ OAT Sensor Bad ? No/Yes OAT STAT _ Economizer Forced? No/Yes ECONFORC Supply Fan Not On 30s? No/Yes SFONSTAT Cool Mode Not In Effect? No/Yes COOL OFF _ OAQ Lockout in Effect? No/Yes OAQLOCKD Econ Recovery Hold Off? No/Yes ECONHELD Dehumid. Disabled Econ.? No/Yes DHDISABL OUTSIDE AIR INFORMATION Outside Air Temperature dF OAT forcible Outside Air Rel. Humidity % OARH forcible Outside Air Enthalpy OAE Outside Air Dewpoint Temp dF OADEWTMP
- EC2Error codeCOOLING INFORMATION Current Running Capacity 0 to 100 % CAPTOTAL 51,52,55,117, 118 Current Cool Stage 0 to 20 COOL STG 51,52,117,118 _ Requested Cool Stage 0 to 20 CL STAGE 51,52,117,118 _ Maximum Cool Stages 0 to 20 CLMAXSTG 51,52,117,118 Active Demand Limit 0 to 100 % DEM LIM forcible 51,52,54,117,118 _ COOL CAP. STAGE CONTROL Capacity Load Factor -400 to 400 SMZ 51-54,117,118 Next Stage EDT Decrease 0 to 30 ^F ADDRISE 51,52,117,118 Next Stage EDT Increase 0 to 30 ^F SUBRISE 52,117,118 Rise Per Percent Capacity 0 to 10 RISE PCT 52,117,118 _ Cap Deadband Subtracting -40 to 0 Y MINUS 52,117,118 _ Cap Deadband Adding 0 to 40 Y PLUS 52,117,118 _ Cap Threshold Subtracting -99 to 0 Z MINUS 52-54,118 _ Cap Threshold Adding 0 to 99 Z PLUS 52-54,118 _ High Temp Cap Override No/Yes HI TEMP 53-54,118 _ Low Temp Cap Override No/Yes LOW TEMP 53-54,118 _ Pull Down Cap Override No/Yes PULLDOWN 53-54,118 Slow Change Cap Override No/Yes SLO CHNG 53-54,118 _
- F1Error codeEPM Fault
- F2Error codeInternal Faults
- L1Error codeAIR TEMPERATURES CONTROL TEMPS Evaporator Discharge Tmp -40 to 240 dF EDT Leaving Air Temperature -40 to 240 dF LAT Mixed Air Temperature -40 to 240 dF MAT Controlling Return Temp -40 to 240 dF RETURN T forcible _ Controlling Space Temp -40 to 240 dF SPACE T forcible _ Air Tmp Lvg Supply Fan -40 to 240 dF SAT Outside Air Temperature -40 - 240 dF OAT forcible Return Air Temperature -40 to 240 dF RAT forcible Space Temperature -40 to 240 dF SPT forcible Space Temperature Offset -10 to 10 ^F SPTO forcible Air Temp Lvg Evap Coil -40 to 240 dF CCT Staged Heat LAT Sum -40 to 240 dF LAT SGAS _ Staged Heat LAT 1 -40 to 240 dF LAT1SGAS Staged Heat LAT 2 -40 to 240 dF LAT2SGAS Staged Heat LAT 3 -40 to 240 dF LAT3SGAS Staged Gas Limit Sw.Temp -40 to 240 dF LIMSWTMP
- P01Error codeLine Voltage: 01 = low line, 02 = high line
- P22Error codeDC BRAKE VOLTAGE 0%
- P25Error codeCurrent limit: (%)
- P26Error codeMotor overload: 100
- P50Error codeFAULT HISTORY - Last 8 faults
- P52Error codeDC BUS VOLTAGE - in percent of nominal. Usu-
- P53Error codeMOTOR VOLTAGE - in percent of rated output
- P54Error codeLOAD - in percent of drives rated output current
- P67Error codeMin alarm
- P68Error codeMax alarm
- S1Error codeGENERAL INPUTS Power Fault Input Normal/Alarm PWRFAULT forcible Main Filter Status Input Clean/Dirty FLTS forcible Post Filter Status Input Clean/Dirty PFLTS forcible Fan request from IGC Off/On IGCFAN Remote Input State Off/On RMTIN forcible Enth. Switch Read High? No/Yes ENTH forcible Supply Fan Status Switch Off/On SFS forcible Freeze Status Switch Normal/Alarm FRZ forcible Plenum Press.Safety Sw. Low/High PPS forcible Air Press.Safety Switch Low/High APS forcible Demand Limit Switch 1 Off/On DMD SW1 forcible _ Demand Limit Switch 2 Off/On DMD SW2 forcible _ Dehumidify Switch Input Off/On DHDISCIN forcible Supply Fan Bypass Input Off/On SFBYIN forcible Power Exh. Bypass Input Off/On PEBYIN forcible
- T048Error codeCktA, Oil Return Not Reliable With Only One Comp Available CktB, Oil Return Not Reliable With Only One Comp Available Circuit A, Compressor 1 Failure Circuit A, Compressor 1 Stuck On Failure Circuit A, Compressor 2 Failure Circuit A, Compressor 2 Stuck On Failure Circuit A, Compressor 3 Failure Circuit A, Compressor 3 Stuck On Failure Circuit B, Compressor 1 Failure Circuit B, Compressor 1 Stuck On Failure Circuit B, Compressor 2 Failure Circuit B, Compressor 2 Stuck On Failure Circuit B, Compressor 3 Failure Circuit B, Compressor 3 Stuck On Failure Circuit A, High Pressure Switch Trip Alert Circuit A, High Pressure Switch Trip Alarm Circuit B, High Pressure Switch Trip Alert Circuit B, High Pressure Switch Trip Alarm Circuit A, Compressor 4 Failure Circuit A, Compressor 4 Stuck On Failure Circuit B, Compressor 4 Failure Circuit B, Compressor 4 Stuck On Failure Circuit A Suction Pressure Alert Circuit B Suction Pressure Alert EXV A1 Superheat Outside Range EXV A2 Superheat Outside Range EXV B1 Superheat Outside Range EXV B2 Superheat Outside Range Circuit A Suction Gas Thermistor Failure Evap. Discharge Reset Sensor Failure Outside Air Temperature Thermistor Failure Space Temperatu
- T093Error codeCirc B Suction Press Transducer Failure Circ A EXV 1 Thermistor Failure Circ A EXV 2 Thermistor Failure Circ B EXV 1 Thermistor Failure Circ B EXV 2 Thermistor Failure Circuit A Liquid Temperature Thermistor Failure Circuit B Liquid Temperature Thermistor Failure Circ A Liquid Press Transducer Failure Circ B Liquid Press Transducer Failure Circuit A Loss of Charge Circuit B Loss of Charge Low Circuit A Charge Detected Low Circuit B Charge Detected High Circuit A Charge Detected High Circuit B Charge Detected Circuit A Low Saturated Suction Temp, Comp Shutdown Circuit A Low Saturated Suction Temperature Alert Circuit A Low Saturated Suction Temperature Alarm Circuit B Low Saturated Suction Temp, Comp Shutdown Circuit B Low Saturated Suction Temperature Alert Circuit B Low Saturated Suction Temperature Alarm Circuit A High Saturated Suction Temperature Circuit B High Saturated Suction Temperature Circuit A High Head Pressure, Comp Shutdown Circuit A High Head Pressure Alert Circuit A High Head Pressure Alarm Circuit B High Head Pressure, Comp Shutdown Circuit B High Head Pressure Alert Circuit B High Head Pressure Alarm Digital Scroll A1 High Discharge Temperature Alert Digital Scrol
- T308Error codeReturn Air Relative Humidity Below Limit Return Air Relative Humidity Above Limit Supply Duct Static Pressure Below Limit Supply Duct Static Pressure Above Limit Building Static Pressure Below Limit Building Static Pressure Above Limit IAQ Above Limit OAT Below Limit OAT Above Limit Static Pressure (SP) Not Holding Setpoint Building Pressure (BP) Not Holding Setpoint DELTACFM Not Holding Setpoint SH A1 Not Holding Setpoint _ SH A2 Not Holding Setpoint _ SH B1 Not Holding Setpoint _ SH B2 Not Holding Setpoint _ Circuit A High Pressure Drop Detected - Check Filter Drier Circuit B High Pressure Drop Detected - Check Filter Drier Heat Not Holding Setpoint Cool Not Holding Setpoint Possible MLV/HGBP Failure Detected SH A1 Flooding Detected _ SH A2 Flooding Detected _ SH B1 Flooding Detected _ SH B2 Flooding Detected _ Excess Outdoor Air Hydronic Freeze Stat Trip Fire Shut Down Emergency Mode (fire-smoke) Evacuation Emergency Mode Pressurization Emergency Mode Smoke Purge Emergency Mode Dirty Main Air Filter Supply Fan Commanded Off, Sensed On Failure Supply Fan Commanded On, Sensed Off Failure Supply Fan VFD Fault Exhaust Fan VFD Fault Dirty Post Air Filter Air Pressure Safety Switch Tr
- T622Error codeEconomizer 2 Actuator Control Range Increased Economizer 2 Actuator Overload, Setpoint Not Reached Economizer 2 Actuator Excessive Utilization Econ 2 (Return) Not Economizing When it Should Econ 2 (Return) Economizing When it Should Not Econ 2 (Return) Damper Stuck or Jammed Humd/HTC-2 Actuator Out of Calibration Humd/HTC-2 Actuator Communication Failure Humd/HTC-2 Actuator Control Range Increased Humd/HTC-2 Actuator Overload, Setpoint Not Reached Humd/HTC-2 Actuator Excessive Utilization Heating Coil Actuator Out of Calibration Heating Coil Actuator Comm Fail Heating Coil Actuator Control Range Increased Heating Coil Actuator Overload, Setpoint Not Reached Heating Coil Actuator Excessive Utilization Economizer 3 Actuator Out of Calibration Economizer 3 Actuator Comm Failure Economizer 3 Actuator Control Range Increased Economizer 3 Actuator Overload, Setpoint Not Reached Economizer 3 Actuator Excessive Utilization Econ 3 (Outside 2) Not Economizing When it Should Econ 3 (Outside 2) Economizing When it Should Not Econ 3 (Outside 2) Damper Stuck or Jammed Heating Actuator 3 Out of Calibration Heating Actuator 3 Comm Failure Heating Actuator 3 Control Range Increased Heating Actuator
- TB201Error code(+)
- U2Error code
- W2Error codeIGC IFO input Fire Shutdown Switch, RA/SA Smoke Detector Thermostat ‘G’ Input Thermostat ‘W2’ Input Thermostat ‘W1’ Input Thermostat ‘Y2’ Input Thermostat ‘Y1’ Input Compressor A1 Feedback Compressor B1 Feedback Compressor A2 Feedback Compressor B2 Feedback Discharge Pressure Circuit A Discharge Pressure Circuit B Suction Pressure Circuit A Suction Pressure Circuit B Return Air Temperature Air Temp Lvg Supply Fan Outside Air Temperature Space Temperature Space Temperature Offset IAQ Input Power Status Input Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used MSP1 Tripped MSP2 Tripped
- X1-28Error codeFactory wired for local equipment network LEN communication
- Y2Error codeABB VFD P.E. or Ret/Exh Fan VFD