Amprobe kelepçe ampermetre All models error codes
Codes
- 2Error codeSet RCD variable trip current
- 7Error code• Loop input select (L-N, L-PE). • Voltage input select (L-N, L-PE, N-PE). • Insulation test: (L-N, L-PE, N-PE) • RCD current rating (10, 30, 100, 300, 500, 1000 mA or VAR)
- 8Error codeRCD Current multiplier (x1/2, x1, x5, AUTO)
- 10Error code• RCD test polarity (0, 180 degrees). • Insulation test voltage (250, 500, or 1000 V)
- 15Error codeLoop impedance - Hi current trip mode
- 20Error codeConfiguration options. Settings you can make within the measurement functions. For example, in the RCD Tripping Time function (PT) you can press F2 to multiply the test current by x1/2, x1, x5 and you can press F3 to select the type of RCD you are testing
- 23Error codeIndicates the selected rotary switch setting. The measurement value in the primary display also corresponds to the switch setting. Rotary switch settings are: V Volts Insulation Continuity RCD trip time Loop no trip RCD trip current Loop hi current trip Phase Rotation
- 24Error codeIndicates that the measured trip current (trip current test) or the measured trip time (trip time test) is according to the appropriate RCD standard and the fault voltage is below the selected limit. For more information, see Maximum Trip Time Table in the Specifications section of this manual
- 25Error codeIndicates the preset fault voltage limit. The default setting is 50 V. Some locations require the fault voltage be set to 25 V, as specified by local electrical codes.
- 29Error codeAppears when the instrument is overheated. The Loop test and RCD functions are inhibited when the instrument is overheated
- 30Error codeAppears when an error occurs. Testing is disabled. See “Error Codes” on page 9 for a listing and explanation of possible error codes
- 31Error codeName of the secondary measurement function. UN Test voltage for insulation test. UF Fault voltage. Measures neutral to earth. PSC Prospective Short Circuit. Calculated from measured voltage and impedance when reading line to neutral. PEFC Prospective Earth Fault Current. Calculated from voltage and loop impedance which is measured line to protective earth. IK In combination with the PSC or PEFC symbol, indicates a short circuit current. RE Earth resistance
- 32Error codeSecondary display and measurement units. Some tests will return more than one result or return a computed value based on the test result. This will occur with: • Volts Secondary display shows line frequency. • Insulation tests Secondary display shows actual test voltage. • Loop/line impedance Secondary display shows PEFC (Prospective Earth Fault Current) or RE PSC (Prospective Short Circuit Current). • RCD switching time Secondary display shows UF fault voltage. • RCD tripping current Secondary display shows UF fault voltage
- 35Error codePotential danger. Appears when measuring or sourcing high voltages
- 200Error codeHi Current mode: ±(2 %)