Alpine endüstriyel öğütme makinesi All models error codes
Codes
- 1Error codeINTERNAL FAULT
- 2Error codeFault code (2nd)
- 3Error codeFault code (3rd)
- 4Error codeFault code (4th)
- 5Error codeFault code (5th)
- 10Error codeTd (Discharge Temperature)
- 11Error codeTm (Outdoor Coil Temperature)
- 12Error codeTb (Defrost Sensor Temperature)
- 13Error codeTl (Liquid Temperature)
- 14Error codePressure Sensor
- 15Error codeThis error indicates the equipment is experiencing frequent low pressure faults
- 16Error codeThis error indicates the equipment is experiencing frequent low pressure faults. Control has determined continued operation is acceptable. This indicates they may be a problem with the equipment
- 17Error codeThis error indicates the equipment is experiencing frequent compressor faults
- 18Error code
- 19Error codeThis error indicates the equipment is experiencing frequent outdoor control board and/or motor faults
- 20Error codeEEV coil is not connected
- 21Error codeThis error indicates the equipment is experiencing frequent low discharge superheat faults
- 22Error codeThis error indicates the equipment is experiencing frequent high discharge temperature faults. Discharge thermistor is not put on correct position
- 23Error codeThe control has detected that the Discharge Temperature Sensor is out of range
- 24Error codeThe high pressure switch is open
- 25Error codeThe outdoor air temperature sensor is open or shorted
- 26Error codeThe control determines that the pressure sensor is not reacting properly
- 27Error codeThe control detects that the Outdoor Defrost Sensor is out of range
- 28Error codeThe control has detected that the Outdoor Coil Temperature Sensor is out of range
- 29Error codeThe control has detected that the Liquid Temperature Sensor is out of range
- 30Error code
- 31Error codeThe control has detected high leakage current (high voltege)
- 32Error codeThis error indicates the equipment is experiencing high temperature faults on the outdoor control board
- 33Error codeThis error indicates the equipment is experiencing high temperature faults on the outdoor control board. Control has determined continued operation is acceptable. This indicates they may be a problem with the equipment
- 34Error codeBoard detected a high current condition. This indicates the potential for a short circuit
- 35Error codeBoard detected a high current condition
- 36Error codeThe control encountered an abnormal condition during the startup procedure
- 37Error code
- 38Error codeThe control has detected a voltage related issue with the compressor
- 39Error code
- 40Error codeControl determines that its compressor requirement is different than the compressor capability
- 41Error codeThe control has detected a low refrigerant condition
- 42Error codeControl detects a low power supply voltage condition
- 43Error codeControl detects a high power supply voltage condition
- 44Error codeThe control detects the outdoor temperature outside recommended operational range. Unit may continue to operate normally
- 45Error codeThe control is unable to start the Cooling mode test because indoor heat has been turned on by thermostat. Please set thermostat to off position
- 46Error codeThe control is unable to sart the Heating mode test becaue indoor heat has been turned on by thermostat. Please set thermostat to off position
- 47Error codeThe control is unable to start the System Verification test because indoor heat has been turned on by thermostat. Please set thermostat to off position
- 48Error codeThe control is unable to enter the Pump Down Mode because indoor heat has been turned on by thermostat. Please set thermostat to off position
- 49Error codeThe control is unable to enter Charging Mode because indoor heat has been turned on by thermostat. Please set thermostat to off position
- 50Error codeThis indicates there is a voltage issue on the control board. See service manual for troubleshooting information
- 51Error codeThis indicates potential communication issues have been detected by the outdoor control board
- 52Error codeThis error indicates the equipment is experiencing frequent compressor faults. Control has determined continued operation is acceptable. This indicates they may be a problem with the equipment
- 53Error codeThis error indicates the equipment is experiencing frequent outdoor control board and/or motor faults. Control has determined continued operation is acceptable. This indicates there may be a problem with the equipment
- 54Error codeThis error indicates the equipment is experiencing frequent low discharge superheat faults. Control has determined continued operation is acceptable. This indicates they may be a problem with the equipment