Alfa Laval PureBallast balast su arıtma sistemi All models error codes
Codes
- 001-399Error codeError number: No. 001 - 399 No. 501 - 699
- 401-499Error codeError number: No. 401 - 499
- AT2222Error codeTemperature input module
- M1Error codeFan rotation in percent of full effect. Fan effect is based on need for cooling. Fan starts at 30 % at 30 C° and rotates at 100 % at 45 C°
- m3Error codeBallast: 32 → 85 Deballast: 17 → 170 Stripping: 17 → 56 During operation, the input flow to the PureBallast system shall be as close as possible to the max flow. This will reduce the stress and wear of the control valve
- MS132Error codeStatus for LPS circuit breaker. Status indication: Green = OK. Grey = Not active. Red = Alarm
- p100Error codeHigh pressure, shutdown trigger (PT201-16)
- p128Error codeMax time communication loss
- p135Error codeExternal system stop
- p141Error codeTimeout: Request "Start BW pump"
- p166Error codePressure PID proportional gain
- p167Error codePressure PID integral time
- p300Error codeHigh filter differential pressure shutdown trigger
- p304Error codePressure setpoint during backflush (PT201-16)
- p305Error codeBackflush trigger: Differential pressure
- p309ParameterIf a backflush pump P309 is not used, pressure drop in pipe 309 must be calculated and added to secure effcient backflush. This is vessel specific and must be calculated using required flow in pipe 309: 15 m3/h. The result of this calculation is used to set parameter p304, crucial for the backflush. See Calculate backflush parameter setting below
- p318Error codeBackflush pump (M703-1)
- p320Error codePreservation pressure setpoint
- p403Error codeCIP pump injection volume
- p405Error codeCIP pump flow rate
- P460Error codePump
- TT401Error codeAir temperature in the electrical cabinet indicated by temperature transmitter TT401